The web interface of 3CX 20 is a bit different than older versions, but the configuration of a beroNet gateway with the IPBX is very similar.
...
On this page, you can create the SIP connection between the 3CX and the gateway. A few important informations need to be entered:
- "Registrar/Server/Gateway Hostname or IP": You need to enter here the IP address of your beroNet Gateway
- Main Trunk Number needs to be assigned a value containing at least four digits
In the authentification part we configure the values which the beronet gateways uses to register to the 3cx:
- "Authentification ID" is what we call "user" in the beroNet web interface
- "Authentification Password" is what we call "secret" in the beroNet web interface
Registering the beroNet gateway
Once the configuration on the 3CX part is done, clique on "generate device config" on the top:
The interface of the beroNet gateway opens. Enter your credentials (admin / admin).
If you use version 16.x, the necessary information are already filled in. Otherwise, you need to enter the IP address of the 3CX, the User and Password set in the authentification part of the 3CX and set hardware information of the VoIP Gateway.
Save and activate the settings to finish the configuration
On the beroNet gateway go to SIP→SIP and click the Add button. In the pop-up fill out the values 3cx provided for registering a SIP trunk, save and click activate.
Go to the state screen to see if registering was successful.