This page will describes how to debug your beroNet LTE-device if something does not work as expected.
...
On-Demand-Support: https://www.beronet.com/support/
Free Support: http://support.beronet.com/
Table of Contents |
---|
...
The SIM-Card is not recognised / does not register or loses registration
If your SIM-card is plugged in the corresponding connector, but the Status on the STATE-Page of the beroNet GUI is red, it means that the SIM was not able to register.
...
The LTE module in the device has its own red LED to show the status of the registration. This is different to the LED’s found on GSM and the front of the device.
The behaviour of the green LED in the front is the following:
OFF - The module has not been initialised by the SBC.
Blinking - The module is initialised and has is searching for a network or does not recognise the SIM
ON - The SIM-Card has been connected to the network
The behaviour of the red LED on the module inside is the following:
...