The t38_options setting in the call configuration string can be used to modify the T38 behaviour of berofix. The general layout is:
t38_options=key1=val1:key2=val2:..
The Settings that can be used are:
plc=0..2 ecm=0/1 Error Correction Mode enable/disable, default 1 rc_fp=0..3 Redundancy Count for Fax Page Data, default 0 rc_t30=0..7 Redundancy Cound for T30 Frames, default 3 fcs=0..6 tcf=0/1 tsp=0/1
an example would be:
t38_options=rc_fp=3